• Puissance : 1 380 – 2 300 kWel
• Rendement électrique pouvant atteindre 45 % (gaz naturel) et 43,6 % (biogaz)
• Très faible consommation d'huile, rendement élevé
• Faibles coûts d'entretien grâce à des intervalles d'entretien espacés
• Conçu pour fonctionner au gaz naturel avec un mélange d'hydrogène pouvant atteindre 25 % en volume
• Disponible en version 50 Hz (V12, V16, V20) et en version 60 Hz (V20)
| TCG 3020 V12 P = Optimized for high electrical efficiency |
TCG 3020 V12 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,380 |
| Electrical efficiency** | % | 45.0 | 44.0 |
| Thermal efficiency** | % | 42.3 | 43.6 |
| Overall efficiency | % | 87.3 | 87.6 |
| Power to heat ratio*** | 1.06 | 1.01 | |
| TCG 3020 V16 P = Optimized for high electrical efficiency |
TCG 3020 V16 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,840 | 1,840 |
| Electrical efficiency** | % | 44.7 | 44.0 |
| Thermal efficiency** | % | 42.6 | 43.6 |
| Overall efficiency | % | 87.3 | 87.6 |
| Power to heat ratio*** | 1.05 | 1.01 | |
| TCG 3020 V20 P = Optimized for high electrical efficiency |
TCG 3020 V20 R = Optimized for high total efficiency |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,300 | 2,300 |
| Electrical efficiency** | % | 45.0 | 44.4 | 44.0 | 43.7 |
| Thermal efficiency** | % | 42.3 | 42.5 | 43.6 | 43.6 |
| Overall efficiency | % | 87.3 | 86.9 | 87.6 | 87.3 |
| Power to heat ratio*** | 1.06 | 1.04 | 1.01 | 1.01 | |
| TCG 3020 V20 PV = Optimized for high efficiency for requested power |
TCG 3020 V20 RV = Optimized for high response for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,000 | 2,000 | 2,000 | 2,000 |
| Electrical efficiency** | % | 44.4 | 43.9 | 43.7 | 43.4 |
| Thermal output | kW | 1,949 | 1,982 | 2,026 | 2,038 |
| Thermal efficiency** | % | 43.3 | 43.5 | 44.2 | 44.2 |
| Overall efficiency | % | 87.7 | 87.4 | 87.9 | 87.6 |
| Power to heat ratio*** | 1.02 | 1.01 | 0.99 | 0.98 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V12 P = Optimized for high electrical efficiency |
TCG 3020 V12 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,380 |
| Electrical efficiency** | % | 43.9 | 42.9 |
| Thermal efficiency** | % | 43.2 | 44.5 |
| Overall efficiency | % | 87.1 | 87.4 |
| Power to heat ratio*** | 1.02 | 0.96 | |
| TCG 3020 V16 P = Optimized for high electrical efficiency |
TCG 3020 V16 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,840 | 1,840 |
| Electrical efficiency** | % | 43.6 | 42.9 |
| Thermal efficiency** | % | 43.5 | 44.5 |
| Overall efficiency | % | 87.1 | 87.4 |
| Power to heat ratio*** | 1.00 | 0.96 | |
| TCG 3020 V20 P = Optimized for high electrical efficiency |
TCG 3020 V20 R = Optimized for high total efficiency |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,300 | 2,300 |
| Electrical efficiency** | % | 44.0 | 43.5 | 42.9 | 42.6 |
| Thermal efficiency** | % | 43.1 | 43.3 | 44.6 | 44.6 |
| Overall efficiency | % | 87.1 | 86.8 | 87.5 | 87.2 |
| Power to heat ratio*** | 1.02 | 1.00 | 0.96 | 0.96 | |
| TCG 3020 V20 PV = Optimized for high efficiency for requested power |
TCG 3020 V20 RV = Optimized for high response for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,000 | 2,000 | 2,000 | 2,000 |
| Electrical efficiency** | % | 43.4 | 42.9 | 42.6 | 42.3 |
| Thermal output | kW | 2,031 | 2,065 | 2,123 | 2,136 |
| Thermal efficiency** | % | 44.1 | 44.3 | 45.2 | 45.2 |
| Overall efficiency | % | 87.5 | 87.2 | 87.8 | 87.5 |
| Power to heat ratio*** | 0.98 | 0.97 | 0.94 | 0.94 | |
| TCG 3020 V12 P = Optimized for high electrical efficiency |
TCG 3020 V12 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,380 |
| Electrical efficiency** | % | 45.0 | 44.0 |
| Thermal efficiency** | % | 42.3 | 43.6 |
| Overall efficiency | % | 87.3 | 87.6 |
| Power to heat ratio*** | 1.06 | 1.01 | |
| TCG 3020 V16 P = Optimized for high electrical efficiency |
TCG 3020 V16 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,840 | 1,840 |
| Electrical efficiency** | % | 44.7 | 44.0 |
| Thermal efficiency** | % | 42.6 | 43.6 |
| Overall efficiency | % | 87.3 | 87.6 |
| Power to heat ratio*** | 1.05 | 1.01 | |
| TCG 3020 V20 P = Optimized for high electrical efficiency |
TCG 3020 V20 R = Optimized for high total efficiency |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,300 | 2,300 |
| Electrical efficiency** | % | 45.0 | 44.4 | 44.0 | 43.7 |
| Thermal efficiency** | % | 42.3 | 42.5 | 43.6 | 43.6 |
| Overall efficiency | % | 87.3 | 86.9 | 87.6 | 87.3 |
| Power to heat ratio*** | 1.06 | 1.04 | 1.01 | 1.01 | |
| TCG 3020 V20 PV = Optimized for high efficiency for requested power |
TCG 3020 V20 RV = Optimized for high response for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,000 | 2,000 | 2,000 | 2,000 |
| Electrical efficiency** | % | 44.4 | 43.9 | 43.7 | 43.4 |
| Thermal output | kW | 1,949 | 1,982 | 2,026 | 2,038 |
| Thermal efficiency** | % | 43.3 | 43.5 | 44.2 | 44.2 |
| Overall efficiency | % | 87.7 | 87.4 | 87.9 | 87.6 |
| Power to heat ratio*** | 1.02 | 1.01 | 0.99 | 0.98 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V12 P = Optimized for high electrical efficiency |
TCG 3020 V12 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,380 |
| Electrical efficiency** | % | 43.9 | 42.9 |
| Thermal efficiency** | % | 43.2 | 44.5 |
| Overall efficiency | % | 87.1 | 87.4 |
| Power to heat ratio*** | 1.02 | 0.96 | |
| TCG 3020 V16 P = Optimized for high electrical efficiency |
TCG 3020 V16 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,840 | 1,840 |
| Electrical efficiency** | % | 43.6 | 42.9 |
| Thermal efficiency** | % | 43.5 | 44.5 |
| Overall efficiency | % | 87.1 | 87.4 |
| Power to heat ratio*** | 1.00 | 0.96 | |
| TCG 3020 V20 P = Optimized for high electrical efficiency |
TCG 3020 V20 R = Optimized for high total efficiency |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,300 | 2,300 |
| Electrical efficiency** | % | 44.0 | 43.5 | 42.9 | 42.6 |
| Thermal efficiency** | % | 43.1 | 43.3 | 44.6 | 44.6 |
| Overall efficiency | % | 87.1 | 86.8 | 87.5 | 87.2 |
| Power to heat ratio*** | 1.02 | 1.00 | 0.96 | 0.96 | |
| TCG 3020 V20 PV = Optimized for high efficiency for requested power |
TCG 3020 V20 RV = Optimized for high response for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,000 | 2,000 | 2,000 | 2,000 |
| Electrical efficiency** | % | 43.4 | 42.9 | 42.6 | 42.3 |
| Thermal output | kW | 2,031 | 2,065 | 2,123 | 2,136 |
| Thermal efficiency** | % | 44.1 | 44.3 | 45.2 | 45.2 |
| Overall efficiency | % | 87.5 | 87.2 | 87.8 | 87.5 |
| Power to heat ratio*** | 0.98 | 0.97 | 0.94 | 0.94 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| Engine type Configuration |
TCG 3020 V12 P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 vol.% hydrogen kit |
TCG 3020 V12 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|
|---|---|---|---|
| Electrical power** | kW | 1,380 | 1,380 |
| Electrical efficiency | % | 44.6 | 43.9 |
| Thermal efficiency (±8 %) | % | 42.5 | 43.6 |
| Total efficiency | % | 87.1 | 87.5 |
| Power to heat ratio *** | 1.05 | 1.00 | |
| Engine type Configuration |
TCG 3020 V16 P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 vol.% hydrogen kit |
TCG 3020 V16 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|
|---|---|---|---|
| Electrical power** | kW | 1,840 | 1,840 |
| Electrical efficiency | % | 44.6 | 43.6 |
| Thermal efficiency (±8 %) | % | 42.6 | 43.9 |
| Total efficiency | % | 87.2 | 87.5 |
| Power to heat ratio *** | 1.05 | 0.99 | |
| Engine type Configuration |
TCG 3020 V20 P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 vol.% hydrogen kit |
TCG 3020 V20 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|
|---|---|---|---|
| Electrical power** | kW | 2,300 | 2,300 |
| Electrical efficiency | % | 44.6 | 43.6 |
| Thermal efficiency (±8 %) | % | 42.6 | 43.9 |
| Total efficiency | % | 87.2 | 87.5 |
| Power to heat ratio*** | 1.05 | 0.99 | |
| Engine type Configuration |
TCG 3020 V20 PV+ High Efficiency for Requested Power plus 25H2-Kit = Optimized for high electrical efficiency at requested power with 25 vol.% hydrogen kit |
TCG 3020 V20 RV+ High Response for Requested Power plus 25H2-Kit = Optimized for high total efficiency at requested power with 25 vol.% hydrogen kit |
|
|---|---|---|---|
| Electrical power** | kW | 2,000 | 2,000 |
| Electrical efficiency | % | 44.0 | 43.3 |
| Thermal efficiency (±8 %) | % | 43,6 | 44,6 |
| Total efficiency | % | 87.6 | 87.9 |
| Power to heat ratio *** | 1.01 | 0.97 | |
* for 5 % O2 and dry exhaust gas
** according to ISO 8528-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V20 Z = Optimized for operation with propane gas |
|||
|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | |
| Electrical output | kW | 1,880 * | 1,880 * |
| Electrical efficiency** | % | 41.8 | 41.5 |
| Thermal output | kW | 2,063 | 2,078 |
| Thermal efficiency** | % | 45.9 | 45.8 |
| Overall efficiency | % | 87.7 | 87.3 |
| Power to heat ratio*** | 0.91 | 0.91 | |
* The electrical output of 1880 kWel is also achieved with natural gas applications.
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V12 X = Optimized for operation with all biogases |
TCG 3020 V16 X = Optimized for operation with all biogases |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,840 |
| Electrical efficiency** | % | 43.6 | 43.6 |
| Thermal efficiency** | % | 42.7 | 42.7 |
| Overall efficiency | % | 86.3 | 86.3 |
| Power to heat ratio*** | 1.02 | 1.02 | |
| TCG 3020 V20 X = Optimized for operation with all biogases |
TCG 3020 V20 XV = Optimized for operation with all biogases for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,000 | 2,000 |
| Electrical efficiency** | % | 43.6 | 43.1 | 43.2 | 42.7 |
| Thermal output | kW | 2,254 | 2,206 | 2,015 | 1,983 |
| Thermal efficiency** | % | 42.9 | 41.4 | 43.5 | 42.3 |
| Overall efficiency | % | 86.5 | 84.5 | 86.7 | 85.0 |
| Power to heat ratio*** | 1.02 | 1.07 | 1.04 | 1.03 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V12 X = Optimized for operation with all biogases |
TCG 3020 V16 X = Optimized for operation with all biogases |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,840 |
| Electrical efficiency** | % | 42.6 | 42.6 |
| Thermal efficiency** | % | 43.4 | 43.5 |
| Overall efficiency | % | 86.0 | 86.1 |
| Power to heat ratio*** | 0.98 | 0.98 | |
| TCG 3020 V20 X = Optimized for operation with all biogases |
TCG 3020 V20 XV = Optimized for operation with all biogases for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,000 | 2,000 |
| Electrical efficiency** | % | 42.7 | 42.2 | 42.2 | 41.7 |
| Thermal output | kW | 2,346 | 2,293 | 2,097 | 2,060 |
| Thermal efficiency** | % | 43.5 | 42.0 | 44.3 | 43.0 |
| Overall efficiency | % | 86.2 | 84.2 | 86.5 | 84.7 |
| Power to heat ratio*** | 0.98 | 1.00 | 1.00 | 0.97 | |
| TCG 3020 V12 P = Optimized for high electrical efficiency |
TCG 3020 V12 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,380 |
| Electrical efficiency** | % | 45.0 | 44.0 |
| Thermal efficiency** | % | 42.3 | 43.6 |
| Overall efficiency | % | 87.3 | 87.6 |
| Power to heat ratio*** | 1.06 | 1.01 | |
| TCG 3020 V16 P = Optimized for high electrical efficiency |
TCG 3020 V16 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,840 | 1,840 |
| Electrical efficiency** | % | 44.7 | 44.0 |
| Thermal efficiency** | % | 42.6 | 43.6 |
| Overall efficiency | % | 87.3 | 87.6 |
| Power to heat ratio*** | 1.05 | 1.01 | |
| TCG 3020 V20 P = Optimized for high electrical efficiency |
TCG 3020 V20 R = Optimized for high total efficiency |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,300 | 2,300 |
| Electrical efficiency** | % | 45.0 | 44.4 | 44.0 | 43.7 |
| Thermal efficiency** | % | 42.3 | 42.5 | 43.6 | 43.6 |
| Overall efficiency | % | 87.3 | 86.9 | 87.6 | 87.3 |
| Power to heat ratio*** | 1.06 | 1.04 | 1.01 | 1.01 | |
| TCG 3020 V20 PV = Optimized for high efficiency for requested power |
TCG 3020 V20 RV = Optimized for high response for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,000 | 2,000 | 2,000 | 2,000 |
| Electrical efficiency** | % | 44.4 | 43.9 | 43.7 | 43.4 |
| Thermal output | kW | 1,949 | 1,982 | 2,026 | 2,038 |
| Thermal efficiency** | % | 43.3 | 43.5 | 44.2 | 44.2 |
| Overall efficiency | % | 87.7 | 87.4 | 87.9 | 87.6 |
| Power to heat ratio*** | 1.02 | 1.01 | 0.99 | 0.98 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V12 P = Optimized for high electrical efficiency |
TCG 3020 V12 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,380 |
| Electrical efficiency** | % | 43.9 | 42.9 |
| Thermal efficiency** | % | 43.2 | 44.5 |
| Overall efficiency | % | 87.1 | 87.4 |
| Power to heat ratio*** | 1.02 | 0.96 | |
| TCG 3020 V16 P = Optimized for high electrical efficiency |
TCG 3020 V16 R = Optimized for high total efficiency |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,840 | 1,840 |
| Electrical efficiency** | % | 43.6 | 42.9 |
| Thermal efficiency** | % | 43.5 | 44.5 |
| Overall efficiency | % | 87.1 | 87.4 |
| Power to heat ratio*** | 1.00 | 0.96 | |
| TCG 3020 V20 P = Optimized for high electrical efficiency |
TCG 3020 V20 R = Optimized for high total efficiency |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,300 | 2,300 |
| Electrical efficiency** | % | 44.0 | 43.5 | 42.9 | 42.6 |
| Thermal efficiency** | % | 43.1 | 43.3 | 44.6 | 44.6 |
| Overall efficiency | % | 87.1 | 86.8 | 87.5 | 87.2 |
| Power to heat ratio*** | 1.02 | 1.00 | 0.96 | 0.96 | |
| TCG 3020 V20 PV = Optimized for high efficiency for requested power |
TCG 3020 V20 RV = Optimized for high response for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,000 | 2,000 | 2,000 | 2,000 |
| Electrical efficiency** | % | 43.4 | 42.9 | 42.6 | 42.3 |
| Thermal output | kW | 2,031 | 2,065 | 2,123 | 2,136 |
| Thermal efficiency** | % | 44.1 | 44.3 | 45.2 | 45.2 |
| Overall efficiency | % | 87.5 | 87.2 | 87.8 | 87.5 |
| Power to heat ratio*** | 0.98 | 0.97 | 0.94 | 0.94 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| Engine type Configuration |
TCG 3020 V12 P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 vol.% hydrogen kit |
TCG 3020 V12 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|
|---|---|---|---|
| Electrical power** | kW | 1,380 | 1,380 |
| Electrical efficiency | % | 44.6 | 43.9 |
| Thermal efficiency (±8 %) | % | 42.5 | 43.6 |
| Total efficiency | % | 87.1 | 87.5 |
| Power to heat ratio *** | 1.05 | 1.00 | |
| Engine type Configuration |
TCG 3020 V16 P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 vol.% hydrogen kit |
TCG 3020 V16 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|
|---|---|---|---|
| Electrical power** | kW | 1,840 | 1,840 |
| Electrical efficiency | % | 44.6 | 43.6 |
| Thermal efficiency (±8 %) | % | 42.6 | 43.9 |
| Total efficiency | % | 87.2 | 87.5 |
| Power to heat ratio *** | 1.05 | 0.99 | |
| Engine type Configuration |
TCG 3020 V20 P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 vol.% hydrogen kit |
TCG 3020 V20 R+ High Response plus 25H2-Kit = Optimized for high total efficiency with 25 vol.% hydrogen kit |
|
|---|---|---|---|
| Electrical power** | kW | 2,300 | 2,300 |
| Electrical efficiency | % | 44.6 | 43.6 |
| Thermal efficiency (±8 %) | % | 42.6 | 43.9 |
| Total efficiency | % | 87.2 | 87.5 |
| Power to heat ratio*** | 1.05 | 0.99 | |
| Engine type Configuration |
TCG 3020 V20 PV+ High Efficiency for Requested Power plus 25H2-Kit = Optimized for high electrical efficiency at requested power with 25 vol.% hydrogen kit |
TCG 3020 V20 RV+ High Response for Requested Power plus 25H2-Kit = Optimized for high total efficiency at requested power with 25 vol.% hydrogen kit |
|
|---|---|---|---|
| Electrical power** | kW | 2,000 | 2,000 |
| Electrical efficiency | % | 44.0 | 43.3 |
| Thermal efficiency (±8 %) | % | 43,6 | 44,6 |
| Total efficiency | % | 87.6 | 87.9 |
| Power to heat ratio *** | 1.01 | 0.97 | |
* for 5 % O2 and dry exhaust gas
** according to ISO 8528-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V20 Z = Optimized for operation with propane gas |
|||
|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | |
| Electrical output | kW | 1,880 * | 1,880 * |
| Electrical efficiency** | % | 41.8 | 41.5 |
| Thermal output | kW | 2,063 | 2,078 |
| Thermal efficiency** | % | 45.9 | 45.8 |
| Overall efficiency | % | 87.7 | 87.3 |
| Power to heat ratio*** | 0.91 | 0.91 | |
* The electrical output of 1880 kWel is also achieved with natural gas applications.
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V12 X = Optimized for operation with all biogases |
TCG 3020 V16 X = Optimized for operation with all biogases |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,840 |
| Electrical efficiency** | % | 43.6 | 43.6 |
| Thermal efficiency** | % | 42.7 | 42.7 |
| Overall efficiency | % | 86.3 | 86.3 |
| Power to heat ratio*** | 1.02 | 1.02 | |
| TCG 3020 V20 X = Optimized for operation with all biogases |
TCG 3020 V20 XV = Optimized for operation with all biogases for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,000 | 2,000 |
| Electrical efficiency** | % | 43.6 | 43.1 | 43.2 | 42.7 |
| Thermal output | kW | 2,254 | 2,206 | 2,015 | 1,983 |
| Thermal efficiency** | % | 42.9 | 41.4 | 43.5 | 42.3 |
| Overall efficiency | % | 86.5 | 84.5 | 86.7 | 85.0 |
| Power to heat ratio*** | 1.02 | 1.07 | 1.04 | 1.03 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| TCG 3020 V12 X = Optimized for operation with all biogases |
TCG 3020 V16 X = Optimized for operation with all biogases |
||
|---|---|---|---|
| Engine type | 50 Hz | 50 Hz | |
| Electrical output | kW | 1,380 | 1,840 |
| Electrical efficiency** | % | 42.6 | 42.6 |
| Thermal efficiency** | % | 43.4 | 43.5 |
| Overall efficiency | % | 86.0 | 86.1 |
| Power to heat ratio*** | 0.98 | 0.98 | |
| TCG 3020 V20 X = Optimized for operation with all biogases |
TCG 3020 V20 XV = Optimized for operation with all biogases for requested power |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Electrical output | kW | 2,300 | 2,300 | 2,000 | 2,000 |
| Electrical efficiency** | % | 42.7 | 42.2 | 42.2 | 41.7 |
| Thermal output | kW | 2,346 | 2,293 | 2,097 | 2,060 |
| Thermal efficiency** | % | 43.5 | 42.0 | 44.3 | 43.0 |
| Overall efficiency | % | 86.2 | 84.2 | 86.5 | 84.7 |
| Power to heat ratio*** | 0.98 | 1.00 | 1.00 | 0.97 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
| Engine type | TCG 3020 V12 50Hz | TCG 3020 V16 50Hz | |
|---|---|---|---|
| Bore / stroke | mm | 170/195 | 170/195 |
| Displacement | dm3 | 53.0 | 71.0 |
| Speed | min-1 | 1,500 | 1,500 |
| Mean piston speed | m/s | 9.8 | 9.8 |
| Length | mm | 5,080 | 6,100 |
| Width | mm | 1,815 | 1,815 |
| Height | mm | 2,190 | 2,190 |
| Dry weight genset | kg | 12,900 | 17,400 |
| TCG 3020 V20 | TCG 3020 V20 Z = Optimized for operation with propane gas |
||||
|---|---|---|---|---|---|
| Engine type | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Bore / stroke | mm | 170/195 | 170/195 | 170/195 | 170/195 |
| Displacement | dm3 | 89.0 | 89.0 | 89.0 | 89.0 |
| Speed | min-1 | 1,500 | 1,500 | 1,500 | 1,500 |
| Mean piston speed | m/s | 9.8 | 9.8 | 9.8 | 9.8 |
| Length | mm | 6,600 | 7,738 | 6,500 | 7,738 |
| Width | mm | 1,815 | 1,815 | 1,815 | 1,815 |
| Height | mm | 2,190 | 2,551 | 2,190 | 2,551 |
| Dry weight genset | kg | 21,400 | 21,200 | 17,980 | 21,200 |
The values given in this table are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
| First Service * |
Cylinder head inspection |
General overhaul |
|
|---|---|---|---|
| High gas quality (natural gas, mine gas (purified) propane gas) |
4,000 oh | 40,000 oh** | 80,000 oh |
| Medium gas quality (biogas (purified), mine gas) |
4,000 oh | 32,000 oh** | 64,000 oh |
| Gas quality Low (biogas, landfill gas, sewage gas) |
3,000 oh | 24,000 oh** | 48,000 oh |
* “after commissioning (E10)”
** at the latest
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.
Des solutions énergétiques conçues sur mesure pour chaque secteur. İltekno propose des solutions énergétiques personnalisées, fiables et performantes, conçues pour répondre aux défis propres à chaque secteur dans les environnements industriels, commerciaux et les infrastructures de services publics à grande échelle.
Des solutions énergétiques adaptées à chaque secteur d'activité. Iltekno propose des solutions d'alimentation électrique sur mesure, efficaces et fiables, conçues pour répondre aux défis spécifiques de chaque secteur, que ce soit dans les environnements industriels, commerciaux ou à grande échelle.