• Plage de puissance de 400 kWel à 1 000 kWel
• Coûts d'installation et d'exploitation considérablement réduits
  Rendement optimal : rendement électrique pouvant atteindre 43 %
• Faible consommation de gaz, utilisation flexible du combustible, compatible avec tous les types de gaz : gaz naturel, biogaz, gaz de décharge, gaz d'égout, gaz de mine, mélanges d'hydrogène et autres gaz

Performance Data – MWM Gas Engine TCG 3016

Natural Gas Applications, NOX ≤ 500 mg/Nm3 * 

 

  TCG 3016 V08
P = Optimized for high electrical efficiency
TCG 3016 V12
P = Optimized for high electrical efficiency
TCG 3016 V16
P = Optimized for high electrical efficiency
Engine type 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Electrical output kW 400 400 600 600 800 800
Medium effective pressure bar 18.9 15.9 18.9 15.7 18.8 15.7
Thermal output ± 8% kW 404 428 617 644 821 856
Electrical efficiency** % 43.1 42.1 43.4 42.4 43.6 42.6
Thermal efficiency** % 43.6 45.0 44.6 45.7 44.6 45.5
Overall efficiency % 86.7 87.1 88.0 88.1 88.2 88.1
Power to heat ratio *** 0.99 0.94 0.97 0.93 0.98 0.94

 

* With 5% O2 and dry exhaust gas
** according to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
 
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.

 

Natural Gas Applications with 25 vol% Hydrogen (NOX ≤ 500 mg/Nm3* / 1.0 g/bhph*)

 

  TCG 3016 V08
P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 Vol.-% Hydrogen Kit
TCG 3016 V12
P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 Vol.-% Hydrogen Kit
Engine type 50 Hz 60 Hz 50 Hz 60 Hz
Electrical output kW 400 400 600 600
Thermal output ± 8% kW 403 423 614 637
Electrical efficiency** % 42.8 41.9 43.0 42.4
Thermal efficiency** % 43.1 44.4 44.1 45.0
Total efficiency % 85.9 86.3 87.1 87.4
Power to heat ratio *** 0.99 0.94 0.98 0.94

 

  TCG 3016 V16
P+ High Efficiency plus 25H2-Kit = Optimized for high electrical efficiency with 25 Vol.-% Hydrogen Kit
TCG 3016 V16
S+ High Density plus 25H2-Kit = Increased power densitiy with 25 Vol.-% Hydrogen Kit
Engine type 50 Hz 60 Hz 50 Hz
Electrical output kW 800 800 1,000
Thermal output ± 8% kW 816 848 1,092
Electrical efficiency** % 43.3 42.2 41.5
Thermal efficiency** % 44.2 45.1 45.7
Total efficiency % 87.5 87.3 87.2
Power to heat ratio *** 0.98 0.94 0.91

 

* for 5 % O2 and dry exhaust gas
** according to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
 
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.

 

Biogas, Landfill Gas, and Sewage Gas Applications, NOx ≤ 500 mg/Nm3 *

 

  TCG 3016 V08
X = Optimized for operation with all biogases
TCG 3016 V12
X = Optimized for operation with all biogases
TCG 3016 V16
X = Optimized for operation with all biogases
Engine type 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Electrical output kW 400 400 600 600 800 800
Medium effective pressure bar 18.9 15.8 18.9 15.8 18.8 15.7
Thermal output ± 8% kW 394 415 598 627 790 827
Electrical efficiency** % 42.8 41.7 42.9 41.7 43.2 41.9
Thermal efficiency** % 42.2 43.3 42.8 43.6 42.7 43.3
Overall efficiency % 85.0 85.0 85.7 85.3 85.9 85.2
Power to heat ratio*** 1.01 0.97 1.00 0.96 1.01 0.97

 

* With 5% O2 and dry exhaust gas
** according to ISO 3046-1
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
 
The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators. 

 

Specifications and Service Intervals – MWM Gas Engine TCG 3016

 

Dimensions and Weights

 

  TCG 3016 V08 TCG 3016 V12 TCG 3016 V16
Engine type 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Bore / stroke mm 132/160 132/160 132/160 132/160 132/160 132/160
Displacement dm3 17.5 17.5 26.3 26.3 35.0 35.0
Speed min-1 1,500 1,800 1,500 1,800 1,500 1,800
Mean piston speed m/s 8.0 9.6 8.0 9.6 8.0 9.6
Length mm 3,100 3,100 3,830 3,830 4,200 4,200
Width mm 1,780 1,780 1,780 1,780 1,780 1,780
Height mm 2,150 2,150 2,150 2,150 2,150 2,150
Dry weight genset kg 5,720 5,720 7,000 7,000 8,070 7,700

 

The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.

 

Service Intervals

 

  First service (check valve clearance) * Spark plug change Cylinder head inspection General overhaul
Natural gas 2,000 Oh *** 4,000 Oh 40,000 Oh ** 80,000 Oh
Purified biogas, landfill gas, and sewage gas 2,000 Oh *** 4,000 Oh 32,000 Oh ** 64,000 Oh
Unpurified biogas, landfill gas, and sewage gas 1,500 Oh 3,000 Oh 24,000 Oh ** 48,000 Oh

 

The data in this chart are for information only and are not binding. The information given in the offer is authoritative. Further generator set variants are available with different generators.

Autres Produits

Des solutions énergétiques conçues sur mesure pour chaque secteur. İltekno propose des solutions énergétiques personnalisées, fiables et performantes, conçues pour répondre aux défis propres à chaque secteur dans les environnements industriels, commerciaux et les infrastructures de services publics à grande échelle.

Applications

Des solutions énergétiques adaptées à chaque secteur d'activité. Iltekno propose des solutions d'alimentation électrique sur mesure, efficaces et fiables, conçues pour répondre aux défis spécifiques de chaque secteur, que ce soit dans les environnements industriels, commerciaux ou à grande échelle.


2.500 +
MegaWatt
Fournir des capacités de production d'électricité à haut rendement dans le cadre de projets énergétiques industriels et à grande échelle à l'échelle mondiale.
310 +
Projets
Des projets d'ingénierie et de production d'électricité menés à bien avec précision, fiabilité et une performance durable.
250 +
Employés
Une équipe d'ingénieurs internationaux hautement qualifiés, vouée à l'excellence dans le domaine des systèmes énergétiques et des solutions innovantes.
25 +
Pays
Une présence mondiale proposant des solutions d'ingénierie énergétique de pointe dans de nombreuses régions et secteurs d'activité.
EXPÉRIENCE ET PARTENARIATS
Une excellence reconnue à travers le monde
Une expertise en ingénierie reconnue dans plus de 20 pays.
Turkey Algeria Nigeria Iraq UK Georgia Cyprus Egypt Ukraine Serbia Mauritania Uzbekistan Guinea etc.
Découvrir plus
itekno Global Presence itekno Global Presence itekno Global Presence
itekno Global Presence